Product Center
A new type of aligner suitable for wafers of different materials and sizes
Suitable for position calibration of different materials such as transparent and semi transparent wafers
A multifunctional CCD laser micrometer is used, which adopts an integrated design of controller and motor driver integrated into the device body
Control mode: Ethernet port or parallel port I/O
Gap and edge shapes that do not meet SEMI specifications can also be customized for design
Can increase the Z-axis to meet the demand for wafer lifting and lowering
| A-100 Standard Specifications | |
| The object being Transported | Various materials, sizes transparent, semi transparent, opaque wafers 2 inches, 4 inches, 6 inches, 8 inches, 12 inches |
| Position Accuracy | Wafer Center:±0.02 mm Wafer Notch, OF angle:±0.05 degrees |
| Time required for location determination | 5 seconds (excluding wafer retrieval time) |
| Sensor | Multi functional CCD laser micrometer |
| Position correction range | Within a radius of 10mm Vacuum adsorption type |
| Wafer adsorption method | |
| Cleanliness | ISO standard Class 2 (under independent exhaust conditions inside the drive structure) Approximately 10 kg |
| Quality | |
| Plant operations | Power supply: AC220V ± 10% 5A Vacuum: -53 kPa or above |
Prev:No More!